NOSHOK® 110-16-4-615-1-40-1-1 NOS 110-16-4-615-1-40-1-1 | Tipco Technologies

NOSHOK® 110-16-4-615-1-40-1-1

NOSHOK® Sanitary Transducer, 2" Sanitary Clamp, ±0.25% Accuracy (BFSL), 0 psig to 15 psig, 4 mA to 20 mA Output, Hirschmann w/ 36 in Cable Attached

  • Manufacturers: NOSHOK
  • Brand Name: NOSHOK®
  • Tipco Part No: NOS 110-16-4-615-1-40-1-1
  • MPN: 110-16-4-615-1-40-1-1
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Register to see Availability

NOSHOK® Sanitary Transducer, 2" Sanitary Clamp, ±0.25% Accuracy (BFSL), 0 psig to 15 psig, 4 mA to 20 mA Output, Hirschmann w/ 36 in Cable Attached

California residents see Prop 65 WARNINGS

Connection Size      :      2 in
Series      :      11 Series Pressure Transducers
Connection Type      :      Sanitary Tri-Clamp®
Pressure Low      :      0 PSI
Pressure High      :      15 PSI
Connection Material      :      316 Stainless Steel
Ambient Temperature Low      :      -40 deg C
Ambient Temperature Low      :      -40 deg F
Ambient Temperature High      :      176 deg F
Ambient Temperature High      :      80 deg C
Operating Temperature Low      :      -40 deg C
Operating Temperature Low      :      212 deg F
Operating Temperature High      :      -40 deg C
Operating Temperature High      :      100 deg F
Media Temperature Low      :      -40 deg C
Media Temperature Low      :      -40 deg F
Media Temperature High      :      150 deg C
Media Temperature High      :      300 deg F
Housing Material      :      316 Stainless Steel
Industry Standards      :      European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Request for Information (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection
Output Signal      :      4 mA to 20 mA, 2-Wire, 0 Vdc to 5 Vdc 3-Wire, 1 Vdc to 5 Vdc 3-Wire, 1 Vdc to 6 Vdc 3-Wire, 0 Vdc to 10 Vdc, 3-Wire, 1 Vdc to 11 Vdc 3-Wire
Electrical Protection      :      Reverse polarity, over-voltage and short circuit protection
Electrical Connection      :      36 in. Cable attached to Hirschmann
Service Life      :      > 100,000,000 Load Cycles
Vibration According to International Electrotechnical Commission (IEC) 60068-2-6      :      150 g
Shock According to International Electrotechnical Commission (IEC) 60068      :      1,000 g
Stability      :      ±0.2% full scale for 1 year, non-accumulating
Compensated Temperature Low      :      0 deg C
Compensated Temperature Low      :      30 deg F
Compensated Temperature High      :      175 deg F
Compensated Temperature High      :      80 deg C
Adjustment      :      ±10% full scale for zero and span
Cover Ring Material      :      Polished Brass
Response Time      :      =10 ms